This note explains how we work out how much each page of this site weighs, and a modelled carbon figure for one view of it, so you can judge the method for yourself.

What we measure

We measure this website only. We do not measure the work we do for clients, or the products we build, here.

Each figure describes one first view of one page by a new visitor, with nothing already stored in their browser.

Step 1: page weight (measured)

When we build the site for a release, a script reads every page in the site's route list and adds up what a browser asks for on first view:

  • the page's own HTML
  • the stylesheets and scripts it links to, including files it asks the browser to load early
  • icons, and images placed in the page or in its inline styles

Text files are measured as we expect them to travel over the network: compressed with Brotli, which we assume our content delivery network (CDN) uses. Images in formats that are already compressed are counted at their file size, as are the newer font formats. Font files in older formats, which compress well, are measured compressed.

Some assets are not certain to be fetched. A font is only downloaded if something on the page uses it, and an image marked to load lazily is only downloaded when a visitor scrolls towards it. We report these separately as an upper bound alongside the headline weight, so the headline never claims more than a first view is certain to fetch.

Page weight is a measurement: we count real files from the real build.

Step 2: from weight to carbon (modelled)

We then convert weight to carbon dioxide equivalent (CO₂e) with the Sustainable Web Design (SWD) model, version 4. CO₂e puts every greenhouse gas on one scale, as the amount of carbon dioxide that would warm the climate by the same amount.

The model works in three moves:

  1. Convert the page weight to gigabytes.
  2. Multiply by the energy used to move and handle each gigabyte, in kilowatt-hours. The model gives separate figures for data centres, networks and visitors' devices, and includes the energy used to make the equipment as well as to run it. The Sustainable Web Design model, version 4, uses 0.300 kWh of energy per GB transferred (0.194 to run the equipment and 0.106 to make it).
  3. Multiply by the carbon intensity of electricity, in grams of CO₂e per kilowatt-hour. We use the model's global average. The model uses 494 g CO₂e per kWh, the global average carbon intensity of electricity (source Ember, 2026).

The result is a modelled figure, not a measurement. We do not meter the electricity used by any visitor or server. No uncertainty range is published for this model. Treat each figure as an estimate of scale.

Where the site is hosted, and why that matters

The site's origin is hosted in London, on Amazon Web Services (AWS) in the eu-west-2 region, and it is served through a global CDN. Visitors are served from whichever edge location is nearest to them, which may be anywhere in the world. So the electricity behind a view is not London's, and we use the global average rather than London's grid.

What we have chosen not to assume

  • No green-hosting discount. We do not reduce the figure for the renewable electricity our providers may buy.
  • No stored copies. We treat every view as a first view. The model can account for returning visitors who already hold part of the page; we do not, because we cannot know who they are.
  • No allowance for what happens after the page loads. Scripts that run later, video that a visitor chooses to play, and interactive 3D scenes loaded after the page appears are outside the figure.

What the figure does not cover

  • Our own laptops, our build servers and the energy used to write and review this site.
  • The visitor's device beyond the share the model attributes to showing a page.
  • Any carbon saving we help clients make. That belongs to the client's own measurement.

When it runs, and how to read it

The measurement runs on every build of the site, including each release. Every figure is reported with the model name and version, the date, and the build it came from, and its label: weight is Measured and CO₂e is Modelled. If the model changes, the version changes with it, and figures from different versions should not be compared without saying so.